AC 2XL · Storage of Cells

AC 2XL15T

AC 2XL15T-S (10) · 10 short canistersItem no. H-AAD1100539

Sales & service for
LN₂ capacity
15L
Holding time
35days
Neck opening
125mm
Height
480mm
Outer Ø
462mm
Your selection
10,320straws

* Nominal values without storage system installed. Actual capacity may vary depending on configuration. ¹ Calculated: value per canister × number of canisters.

Version
01 2 options ·
1 × AC 2XL15T-S (10) €1,210.00
€1,210.00excl. VAT · plus shipping
Request a quote
⇄ Compare
Lifetime parts supplyCanisters, lids, racks and more
ShippingParcels via DHL or UPS, freight via forwarding carrier
AdviceTalk to a cryogenic engineer
Sales & service forAuguste Cryogenics
Overview

The vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.

The individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.

  • High mobility due to low weight and compact dimensions
  • Long holding times with low nitrogen consumption
  • Large storage capacity
  • T-models with ADR approval – transportable in accordance with dangerous goods regulations
MDR

MDR – Medical Device Regulation (EU)

The Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.

AC 2XL15T: MDR version available

ADR · T-Models

T-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.

✓ AC 2XL15T: ADR transportable

Full description

The vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.

Key Features:

  • High mobility due to low weight and compact dimensions
  • Long holding times with low nitrogen consumption
  • Large storage capacity
  • T-models with ADR approval – transportable in accordance with dangerous goods regulations

The individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.

A complete overview of all technical parameters for this container is provided in the “Technical Data” table below.


Overview of further models for CELL STORAGE:

T-Models
T-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.

Example: AC L20-S (standard) and AC L20T-S (T-version).

AC FREEZER 
Freezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.


If you need assistance selecting the appropriate container, please consult our guide “Cryogenic Cell Storage: The Guide to Selecting the Right Container” or contact us directly.

 

MDR – Medical Device Regulation (EU)
The Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.

 

* The values given are nominal values, determined without a storage system and under
precisely defined conditions. Depending on the operating conditions and the
storage system used, the actual values may vary considerably.
In the course of continuous product improvement and development,
we reserve the right to change the specifications at any time without prior notice.

 

Including 10 short canisters

 

Note: The product image is a sample illustration.

 

Specifications

Incl. 10 short canisters

LN2 capacity (liters): 15 
Empty weight (kg):
Neck opening (mm): 125 
Outside diameter (mm): 462
Total height (mm): 480 
Static evaporation rate (liters/day): 
Static hold time (days): 35

Download brochure (PDF)

Dimensions · mm 480 Ø 462Ø 125
Datasheet AC 2XL15T-S (10)All values for your selection.

Performance

LN₂ capacity
15 L
Holding time
35 days
Neck opening
125 mm

Storage

Storage system
10 short canisters
Straws 0.25 ml
10,320 (10 × 1,032)
Straws 0.5 ml
4,490 (10 × 449)

Further data

Max. canister capacity
10

Dimensions

Height
480 mm
Outside diameter
462 mm
Canister Ø × height
70 × 110 mm

Shipping

Packing dimensions
490 × 490 × 660 mm
Shipping weight
12.3 kg

Order

SKU
AC 2XL15T-S (10)
Item number
H-AAD1100539
Scope of delivery
10 short canisters
ADR
ADR transportable
MDR
Optionally available as a medical device
Version
Standard
Price
€1,210.00 excl. VAT

* Nominal values without storage system installed. Actual capacity may vary depending on configuration. ¹ Calculated: value per canister × number of canisters. Gold values change with your selection.

Storage system

What goes inside
the AC 2XL15T.

Tap a position for its content.

1 2 3 4 5 6 7 8 9 10 NECK OPENING 125Ø 462 mm
Top view

10 short canisters

The short canisters are primarily used for the storage of cryogenic straws.

10,320Straws 0.25 ml
4,490Straws 0.5 ml

Position 1 · Short canister

  • 1,032 straws 0.25 ml per canister
  • Canister diameter: Ø 70 mm
  • Canister height: 110 mm
  • Scope of delivery: 10 short canisters
Matching inventory →

* Nominal values without storage system installed. Actual capacity may vary depending on configuration. ¹ Calculated: value per canister × number of canisters.

Compare against its neighbours

One size down, one size up.

To scale on one baseline. Gold = best value in the row. The tags show the difference to the AC 2XL15T.

Model
AC 2XL15T-S (10)This model
LN₂ capacityL
15
31.5+16.5
Holding timedays
35
90+55
EvaporationL/day
–
0.35
Straws 0.25 ml
10,320
11,952+1,632
Neck openingmm
125
125same
Height · Ømm
480 · 462
717 · 462
Empty weightkg
–
13
Price fromexcl. VAT
€1,210.00
€1,073.00−€137.00
15models in the AC 2XL series

See every model side by side

Filter by capacity, holding time and storage system, sort any column.

Open full comparison tool →

* Nominal values without storage system installed. Actual capacity may vary depending on configuration. ¹ Calculated: value per canister × number of canisters.

Not sure it is the right size?

Let the finder decide in five questions.

Sample type, quantity, holding time and access: the cell storage finder suggests the matching vessel and storage system.