{"product_id":"ac-180-lp-low-pressure","title":"AC 180 LP - Low Pressure","description":"\u003cp data-mce-fragment=\"1\"\u003eThe vessels in the AC Liquid Cylinders Series are storage and transport cylinders for liquefied gas. The product line represent an important component of the Auguste Cryogenics product portfolio. The trusted products have been successfully operating throughout Europe and all over the world for decades.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe inner and outer vessel are constructed of top grade stainless steel. The ultra-low evaporation rates are ensured by a special super insulation and the Auguste Cryogenics GOLD Standard vacuum technology.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOf course all cylinders of the Auguste Cryogenics AC Liquid Cylinder Series comply with the European Directive 2010\/35\/EU for transportable pressure equipment (TPED), making them flexible and valuable elements in the liquefied gases supply chain in various industrial, medical, research and food production applications.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAuguste Cryogenics‘ AC Liquid Cylinders come in several sizes from 70 to 240 liters net volume and are available without or with pressure building. They are transportable units, designed and built to rugged construction standards that are intended to be carried full. They are engineered for either low-pressure applications of cryogenic filling and liquid dispensing or high-pressure gas distribution. All units feature quick and easy liquid withdrawal.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe road-transportable cylinders are also available equipped with an automatic pressurebuilding circuit. There is also an integrated economizer circuit that helps reduce and control overflow gas consumption. This is designed in order to help conserve gas during low demand periods and build up pressure quickly for peak demand.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Auguste Cryogenic AC series is the industry standard for gas liquid cylinder performance and feature Auguste Cryogenics‘ GOLD Standard vacuum technology.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eLow pressure liquid cylinders\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThese cylinders are transportable units, designed and built to rugged construction standards that are intended to be carried full of product. These vessels are available with or without a built-in pressure building coil. All units feature quick and easy liquid withdrawal.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMedium and high pressure liquid cylinders\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach vessel in this series of road-transportable cylinders features a pressure building circuit. There is also an integrated economizer circuit that helps reduce and control overflow gas consumption. The optimized design helps to conserve boil off gas during low demand periods and build up pressure quickly for peak demand.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Auguste Cryogenic AC line represents the GOLD standard for industrial gas liquid cylinder performance.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\" data-mce-fragment=\"1\"\u003e\n\u003ctable style=\"width: 550px;\" class=\"iksweb\" data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth style=\"width: 176.938px;\" class=\"lefr-col\" data-mce-fragment=\"1\"\u003e\u003c\/th\u003e\n\u003cth style=\"width: 355.062px; text-align: left;\" data-mce-fragment=\"1\"\u003eLiquid Cylinder Product Line General Technical Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 176.938px;\" class=\"lefr-col\" data-mce-fragment=\"1\"\u003eInner and outer vessel\u003c\/td\u003e\n\u003ctd style=\"width: 355.062px; text-align: left;\" data-mce-fragment=\"1\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 176.938px;\" class=\"lefr-col\" data-mce-fragment=\"1\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"width: 355.062px; text-align: left;\" data-mce-fragment=\"1\"\u003eMultilayer super insulation and high quality vaccuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 176.938px;\" class=\"lefr-col\" data-mce-fragment=\"1\"\u003eApproval\u003c\/td\u003e\n\u003ctd style=\"width: 355.062px; text-align: left;\" data-mce-fragment=\"1\"\u003eTPED 2010\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 176.938px;\" class=\"lefr-col\" data-mce-fragment=\"1\"\u003eSafety valve set to | \u003cspan data-mce-fragment=\"1\"\u003eMax. allowed working pressure (MAWP)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 355.062px; text-align: left;\" data-mce-fragment=\"1\"\u003e1.5 | 10 bar for N₂, O₂, Ar\u003cbr data-mce-fragment=\"1\"\u003e15.9 | 15.9 bar for N₂, O₂, Ar\u003cbr data-mce-fragment=\"1\"\u003e24 | 24 bar for N₂, O₂, Ar, CO₂ and N₂O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 176.938px;\" class=\"lefr-col\" data-mce-fragment=\"1\"\u003eEnd fittings\u003c\/td\u003e\n\u003ctd style=\"width: 355.062px; text-align: left;\" data-mce-fragment=\"1\"\u003eCGA 295 for N₂, Ar, CO₂ and N₂O | CGA 540 for O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cb\u003eTechnical Data\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 550px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 18.625px;\"\u003e\n\u003cth style=\"height: 18.625px; width: 271.719px;\" class=\"lefr-col\"\u003eAC 180 LP\u003c\/th\u003e\n\u003cth style=\"height: 18.625px; width: 261.281px;\"\u003ePart No. ALC180-0\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eGross capacity (Liter)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eNet capacity (Liter)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eWork. pressure std. | max. (bar)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e1.5 | 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eEvaporation on rate (N₂\/%\/day)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eLiquid withdrawal rate (l\/min)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eWeight empty (kg)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eWeight ﬁlled w. N₂ (kg)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eHeight (mm)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e1780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eDiameter(mm)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eCastors\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eAuto. pressure building\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e750*750*1930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e1,086\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 271.719px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 261.281px;\"\u003e157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eDownload Datasheet\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Download Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC_Liquid_Cylinders_-_Product_Sheets_EN_2.pdf?v=1698401759\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"55\" height=\"58\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Liquid-Cylinders-brochure-EN.pdf?v=1608219304\" title=\"Download Datasheet\" class=\"datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"55\" height=\"58\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords 180LowPressure 180Niederdruck AC180LP AC180 AC18 AC1 180 Niederdruck Liquid Cylinder Lagerung und Transport von Stickstoff Die Flüssigstickstofflager- und Transportbehälter Edelstahlbehälter Kryobehälter Mobiler Stickstoffbehälter Stickstoff Vorratsbehälter Flüssigstickstoff Druckbehälter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eGross capacity (Liter): 186 \u003cbr\u003eNet capacity (Liter): 180 \u003cbr\u003eWork. pressure std. | max. (bar): 1.5 | 10 \u003cbr\u003eEvaporation on rate (N₂\/%\/day): 1.3 \u003cbr\u003eLiquid withdrawal rate (l\/min): 6 \u003cbr\u003eWeight empty (kg): 137 \u003cbr\u003eWeight ﬁlled w. N₂ (kg): 282\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"Default Title","offer_id":68299488657629,"sku":"AC 180 LP","price":7359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/AC180LP_Nitrogen_Storage_Cryogenic_Nitrogen_Container_1Kopie.png?v=1793045915","url":"https:\/\/intl.cryonos.shop\/products\/ac-180-lp-low-pressure","provider":"Cryonos GmbH","version":"1.0","type":"link"}