{"title":"AC L","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003c\/p\u003e\n\u003cp\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" rel=\"noopener\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cryonos.shop\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e#datasheet\u003c\/p\u003e\n\u003cp\u003e#info-tags\u003c\/p\u003e\n\u003cp\u003eProduct name definition:\u003cbr\u003e\u003cspan style=\"color: rgb(225, 198, 43);\"\u003e\u003cstrong\u003eAC:\u003c\/strong\u003e\u003c\/span\u003e Auguste Cryogenics (manufacturer name) \/\/ \u003cspan style=\"color: rgb(225, 198, 43);\"\u003e\u003cstrong\u003eL:\u003c\/strong\u003e\u003c\/span\u003e Neck opening 50 mm (exception: AC L2-S) \/\/ \u003cspan style=\"color: rgb(225, 198, 43);\"\u003e\u003cstrong\u003eNumber (e.g. 10):\u003c\/strong\u003e\u003c\/span\u003e Volume in liters \/\/ \u003cstrong\u003e\u003cspan style=\"color: rgb(225, 198, 43);\"\u003eT:\u003c\/span\u003e\u003c\/strong\u003e Reinforced version, intended for transport according to ADR directive \/\/ \u003cstrong\u003e\u003cspan style=\"color: rgb(225, 198, 43);\"\u003e-S:\u003c\/span\u003e\u003c\/strong\u003e Short canisters | \u003cspan style=\"color: rgb(225, 198, 43);\"\u003e\u003cstrong\u003e-L:\u003c\/strong\u003e\u003c\/span\u003e Long canisters\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","products":[{"product_id":"ac-l2-s-1","title":"AC L2-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 541px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 286.609px;\" class=\"lefr-col\"\u003eAC L2-S\u003c\/th\u003e\n\u003cth style=\"width: 237.391px;\"\u003ePart No. H-AAD1100010\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e2,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e0,07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e260*260*465\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e0,031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 237.391px;\"\u003e4,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 3 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL2 ACL2S ACL2-S L2 L2-S L10S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage AC L2-S AC L2 S AC L2S AC L 2-S AC L 2 S AC L 2S ACL2-S ACL2S L2-S L2 S L2S L 2-S L 2 S L 2S AC L-2-S AC LS2 L2S AC AC L2 AC L 2 L2 AC L cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter AC L2-S AC L2S L2-S Auguste Cryogenics AC L2-S AC L2-S liquid nitrogen container AC L2-S cryogenic storage vessel AC L2-S Flüssigstickstoffbehälter und AC L2-S Kryobehälter H-AAD1100010 HAAD1100010 H AAD1100010 H-AAD-1100010 AAD1100010 AAD 1100010 1100010\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 3 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 2\u003cbr\u003eEmpty weight (kg): 2,8\u003cbr\u003eNeck opening (mm): 30\u003cbr\u003eOutside diameter (mm): 223\u003cbr\u003eTotal height (mm): 407\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,07\u003cbr\u003eStatic hold time (days): 28\u003cbr\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299475910877,"sku":"AC L2-S (1)","price":451.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299475943645,"sku":"AC L2-S (1) - MDR","price":542.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL2-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044467"},{"product_id":"ac-l3-s","title":"AC L3-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 279.625px;\"\u003eAC L3-S\u003c\/th\u003e\n\u003cth style=\"width: 258.375px;\"\u003ePart No. H-AAD1100011\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e3,15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e3,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e270*270*510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e0,037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 279.625px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 258.375px;\"\u003e4,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL3 ACL3S ACL3-S L3 L3-S L3S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage AC L3-S AC L3 S AC L3S AC L 3-S AC L 3 S AC L 3S ACL3-S ACL3S L3-S L3 S L3S L 3-S L 3 S L 3S AC L-3-S AC LS3 L3S AC AC L3 AC L 3 L3 AC L H-AAD1100011 HAAD1100011 H AAD1100011 H-AAD-1100011 AAD1100011 AAD 1100011 1100011 Auguste Cryogenics AC L3-S AC L3-S liquid nitrogen container AC L3-S cryogenic storage vessel AC L3-S Flüssigstickstoffbehälter AC L3-S Kryobehälter cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 3,15\u003cbr\u003eEmpty weight (kg): 3,1\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 223\u003cbr\u003eTotal height (mm): 438\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 26\u003cbr\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299476074717,"sku":"AC L3-S","price":468.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299476107485,"sku":"AC L3-S - MDR","price":561.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL3-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044473"},{"product_id":"ac-l6-s","title":"AC L6-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 269.141px;\"\u003eAC L6-S\u003c\/th\u003e\n\u003cth style=\"width: 267.859px;\"\u003ePart No. H-AAD1100061\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e4,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e496\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 269.141px; text-align: left;\"\u003eStraw holding capacity 0,25 ml (-S)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 269.141px; text-align: left;\"\u003eStraw holding capacity 0,5 ml (-S)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e340*340*555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e0,064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 269.141px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 267.859px;\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL6 ACL6S ACL6-S L6 L6-S L6S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage Auguste Cryogenics AC L6-S AC L6-S liquid nitrogen container AC L6-S cryogenic storage vessel AC L6-S Flüssigstickstoffbehälter AC L6-S Kryobehälter AC L6 S AC L6S ACL6-S ACL6S L6-S L6 S L6S L 6-S L 6 S L 6S AC L-6-S AC LS6 L6S AC AC L6 AC L 6 L6 AC L H-AAD1100061 HAAD1100061 H AAD1100061 H-AAD-1100061 AAD1100061 AAD 1100061 1100061 cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 6\u003cbr\u003eEmpty weight (kg): 4,8\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 300\u003cbr\u003eTotal height (mm): 496\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 52\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299476861149,"sku":"AC L6-S","price":548.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299476893917,"sku":"AC L6-S - MDR","price":658.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL6_Cell_Storage_Cryogenic_Nitrogen_Container_1_425000a9-4644-40e4-8772-9b86a4607c29.png?v=1793044500"},{"product_id":"ac-l10-s","title":"AC L10-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 541px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 291.609px;\" class=\"lefr-col\"\u003eAC L10-S\u003c\/th\u003e\n\u003cth style=\"width: 232.391px;\"\u003ePart No. H-AAD1100007\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e6,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e552\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e340*340*615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e0,071\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 291.609px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 232.391px;\"\u003e7,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL10 ACL10S ACL10-S L10 L10-S L10S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L10-S AC L10-S liquid nitrogen container AC L10-S cryogenic storage vessel AC L10-S Flüssigstickstoffbehälter AC L10-S Kryobehälter AC L10 S AC L10S ACL10-S ACL10S L10-S L10 S L10S L 10-S L 10 S L 10S AC L-10-S AC LS10 L10S AC AC L10 AC L 10 L10 AC L H-AAD1100007 HAAD1100007 H AAD1100007 H-AAD-1100007 AAD1100007 AAD 1100007 1100007\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 10\u003cbr\u003eEmpty weight (kg): 6,1\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 300\u003cbr\u003eTotal height (mm): 552\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 86\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299476992221,"sku":"AC L10-S","price":559.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299477024989,"sku":"AC L10-S - MDR","price":671.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/1.IMG_20191218_101341.png?v=1793044506"},{"product_id":"ac-l13-s","title":"AC L13-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\"\u003eAC L13-S\u003c\/th\u003e\n\u003cth\u003ePart No. H-AAD1100299\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd\u003e6,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd\u003e627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd\u003e350*350*690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd\u003e0,085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd\u003e9,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL13 ACL13S ACL13-S L13 L13-S L13S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L13-S AC L13-S liquid nitrogen container AC L13-S cryogenic storage vessel AC L13-S Flüssigstickstoffbehälter AC L13-S Kryobehälter AC L13 S AC L13S ACL13-S ACL13S L13-S L13 S L13S L 13-S L 13 S L 13S AC L-13-S AC LS13 L13S AC AC L13 AC L 13 L13 AC L H-AAD1100299 HAAD1100299 H AAD1100299 H-AAD-1100299 AAD1100299 AAD 1100299 1100299\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 13\u003cbr\u003eEmpty weight (kg): 6,3\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 310\u003cbr\u003eTotal height (mm): 627\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 109\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299477582045,"sku":"AC L13-S","price":719.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299477614813,"sku":"AC L13-S - MDR","price":862.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL13-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044527"},{"product_id":"ac-l13-l","title":"AC L13-L - Long Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"iksweb\" style=\"width: 541px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 307.609px;\"\u003eAC L13-L\u003c\/th\u003e\n\u003cth style=\"width: 213.391px;\"\u003ePart No. H-AAD1100065\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e6,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e2934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e1284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003e2ml Vials capacity\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e350*350*690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e0,085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 307.609px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 213.391px;\"\u003e9,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL13 ACL13L ACL13-L L13 L13-L L13L Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L13-L AC L13-L liquid nitrogen container AC L13-L cryogenic storage vessel AC L13-L Flüssigstickstoffbehälter AC L13-L Kryobehälter AC L13 L AC L13L ACL13-L ACL13L L13-L L13 L L13L L 13-L L 13 L L 13L AC L-13-L AC LS13 L13L AC AC L13 AC L 13 L13 AC L H-AAD1100065 HAAD1100065 H AAD1100065 H-AAD-1100065 AAD1100065 AAD 1100065 1100065\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 13\u003cbr\u003eEmpty weight (kg): 6,3\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 310\u003cbr\u003eTotal height (mm): 627\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 109\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299478073565,"sku":"AC L13-L","price":742.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299478106333,"sku":"AC L13-L - MDR","price":890.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL13-L_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044538"},{"product_id":"ac-l15-s","title":"AC L15-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 541px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 288.609px;\"\u003eAC L15-S\u003c\/th\u003e\n\u003cth style=\"width: 235.391px;\"\u003ePart No. H-AAD1100067\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e8,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e425*425*655\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e0,118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.609px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 235.391px;\"\u003e11,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL15 ACL15S ACL15-S L15 L15-S L15S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L15-S AC L15-S liquid nitrogen container AC L15-S cryogenic storage vessel AC L15-S Flüssigstickstoffbehälter AC L15-S Kryobehälter AC L15 S AC L15S ACL15-S ACL15S L15-S L15 S L15S L 15-S L 15 S L 15S AC L-15-S AC LS15 L15S AC AC L15 AC L 15 L15 AC L H-AAD1100067 HAAD1100067 H AAD1100067 H-AAD-1100067 AAD1100067 AAD 1100067 1100067\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 16\u003cbr\u003eEmpty weight (kg): 8,5\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 394\u003cbr\u003eTotal height (mm): 600\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 134\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299478597853,"sku":"AC L15-S","price":776.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299478630621,"sku":"AC L15-S - MDR","price":931.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL15-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044555"},{"product_id":"ac-l20-s","title":"AC L20-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px; height: 352.688px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eAC L20-S\u003c\/th\u003e\n\u003cth style=\"width: 255.375px; height: 19.5938px;\"\u003ePart No. H-AAD1100072\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e9,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e425*425*735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e0,133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.625px; height: 19.5938px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 255.375px; height: 19.5938px;\"\u003e12,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL20 ACL20S ACL20-S L20 L20-S L10S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L20-S AC L20-S liquid nitrogen container AC L20-S cryogenic storage vessel AC L20-S Flüssigstickstoffbehälter AC L20-S Kryobehälter AC L20 S AC L20S ACL20-S ACL20S L20-S L20 S L20S L 20-S L 20 S L 20S AC L-20-S AC LS20 L20S AC AC L20 AC L 20 L20 AC L H-AAD1100072 HAAD1100072 H AAD1100072 H-AAD-1100072 AAD1100072 AAD 1100072 1100072\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 20\u003cbr\u003eEmpty weight (kg): 9,5\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 394\u003cbr\u003eTotal height (mm): 675\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 168\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299479384285,"sku":"AC L20-S","price":833.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299479417053,"sku":"AC L20-S - MDR","price":1000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL20-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044586"},{"product_id":"ac-l25-s","title":"AC L25-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 288.156px;\"\u003eAC L25-S\u003c\/th\u003e\n\u003cth style=\"width: 248.844px;\"\u003ePart No. H-AAD1100077\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e10,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e0,14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e425*425*765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e0,138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 288.156px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 248.844px;\"\u003e14,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL25 ACL25S ACL25-S L25 L25-S L25S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L25-S AC L25-S liquid nitrogen container AC L25-S cryogenic storage vessel AC L25-S Flüssigstickstoffbehälter AC L25-S Kryobehälter AC L25 S AC L25S ACL25-S ACL25S L25-S L25 S L25S L 25-S L 25 S L 25S AC L-25-S AC LS25 L25S AC AC L25 AC L 25 L25 AC L H-AAD1100077 HAAD1100077 H AAD1100077 H-AAD-1100077 AAD1100077 AAD 1100077 1100077\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters) 25\u003cbr\u003eEmpty weight (kg) 10,7\u003cbr\u003eNeck opening (mm) 50\u003cbr\u003eOutside diameter (mm) 394\u003cbr\u003eTotal height (mm) 705\u003cbr\u003eStatic evaporation rate (liters \/ day) 0,14\u003cbr\u003eStatic hold time (days) 175\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299479548125,"sku":"AC L25-S","price":844.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299479580893,"sku":"AC L25-S - MDR","price":1013.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL25-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044592"},{"product_id":"ac-l20-l","title":"AC L20-L - Long Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 555px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 286.609px;\" class=\"lefr-col\"\u003eAC L20-L\u003c\/th\u003e\n\u003cth style=\"width: 251.391px;\"\u003ePart No. H-AAD1100073\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e9,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e2934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e1284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003e2ml Vials capacity\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e425*425*735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e0,133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 286.609px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 251.391px;\"\u003e12,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL20 ACL20L ACL20-L L20 L20-L L20L Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L20-L AC L20-L liquid nitrogen container AC L20-L cryogenic storage vessel AC L20-L Flüssigstickstoffbehälter AC L20-L Kryobehälter AC L20 L AC L20L ACL20-L ACL20L L20-L L20 L L20L L 20-L L 20 L L 20L AC L-20-L AC LS20 L20L AC AC L20 AC L 20 L20 AC L H-AAD1100073 HAAD1100073 H AAD1100073 H-AAD-1100073 AAD1100073 AAD 1100073 1100073\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 20\u003cbr\u003eEmpty weight (kg): 9,5\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 394\u003cbr\u003eTotal height (mm): 675\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 168\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299479843037,"sku":"AC L20-L","price":856.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299479875805,"sku":"AC L20-L - MDR","price":1027.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL20-L_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044604"},{"product_id":"ac-l25-l","title":"AC L25-L - Long Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 297.625px;\"\u003eAC L25-L\u003c\/th\u003e\n\u003cth style=\"width: 240.375px;\"\u003ePart No. H-AAD1100001\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e10,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e0,14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e2934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e1284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003e2ml Vials capacity\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e425*425*765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e0,138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 297.625px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 240.375px;\"\u003e14,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL25 ACL25L ACL25-L L25 L25-L L25L Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L25-L AC L25-L liquid nitrogen container AC L25-L cryogenic storage vessel AC L25-L Flüssigstickstoffbehälter AC L25-L Kryobehälter AC L25 L AC L25L ACL25-L ACL25L L25-L L25 L L25L L 25-L L 25 L L 25L AC L-25-L AC LS25 L25L AC AC L25 AC L 25 L25 AC L H-AAD1100001 HAAD1100001 H AAD1100001 H-AAD-1100001 AAD1100001 AAD 1100001 1100001\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 25\u003cbr\u003eEmpty weight (kg): 10,7\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 394\u003cbr\u003eTotal height (mm): 705\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,14\u003cbr\u003eStatic hold time (days): 175\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299480563933,"sku":"AC L25-L","price":878.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299480596701,"sku":"AC L25-L - MDR","price":1054.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/1.IMG_20191218_131909.png?v=1793044632"},{"product_id":"ac-l30-s","title":"AC L30-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 282.203px;\"\u003eAC L30-S\u003c\/th\u003e\n\u003cth style=\"width: 253.797px;\"\u003ePart No. H-AAD1100082\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e31,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e12,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e462\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e480*480*900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e0,207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.203px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 253.797px;\"\u003e15,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL30 ACL30S ACL30-S L30 L30-S L30S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L30-S AC L30-S liquid nitrogen container AC L30-S cryogenic storage vessel AC L30-S Flüssigstickstoffbehälter AC L30-S Kryobehälter AC L30 S AC L30S ACL30-S ACL30S L30-S L30 S L30S L 30-S L 30 S L 30S AC L-30-S AC LS30 L30S AC AC L30 AC L 30 L30 AC L H-AAD1100082 HAAD1100082 H AAD1100082 H-AAD-1100082 AAD1100082 AAD 1100082 1100082\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 31,5\u003cbr\u003eEmpty weight (kg): 12,9\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 462\u003cbr\u003eTotal height (mm): 712\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 254\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299481350365,"sku":"AC L30-S","price":901.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299481383133,"sku":"AC L30-S - MDR","price":1082.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/1.IMG_20191219_154430.png?v=1793044666"},{"product_id":"ac-l30-l","title":"AC L30-L - Long Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 555px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 288.141px;\" class=\"lefr-col\"\u003eAC L30-L\u003c\/th\u003e\n\u003cth style=\"width: 248.859px;\"\u003ePart No. H-AAD1100083\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e31,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e12,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e462\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003e\u003cspan\u003eCanister Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e2934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e1284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003e2ml Vials capacity\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e480*480*900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e0,207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288.141px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 248.859px;\"\u003e15,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL30 ACL30L ACL30-L L30 L30-L L30L Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L30-L AC L30-L liquid nitrogen container AC L30-L cryogenic storage vessel AC L30-L Flüssigstickstoffbehälter AC L30-L Kryobehälter AC L30 L AC L30L ACL30-L ACL30L L30-L L30 L L30L L 30-L L 30 L L 30L AC L-30-L AC LS30 L30L AC AC L30 AC L 30 L30 AC L H-AAD1100083 HAAD1100083 H AAD1100083 H-AAD-1100083 AAD1100083 AAD 1100083 1100083\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 31,5\u003cbr\u003eEmpty weight (kg): 12,9\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 462\u003cbr\u003eTotal height (mm): 712\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 254\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299482038493,"sku":"AC L30-L","price":935.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299482071261,"sku":"AC L30-L - MDR","price":1122.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/1.IMG_20191219_155039.png?v=1793044688"},{"product_id":"ac-l35-s","title":"AC L35-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 555px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 282.125px;\" class=\"lefr-col\"\u003eAC L35-S\u003c\/th\u003e\n\u003cth style=\"width: 254.875px;\"\u003ePart No. H-AAD1100251\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e35,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e14,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e462\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e758\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e286\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e480*480*915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e0,211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 282.125px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 254.875px;\"\u003e18,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL35 ACL35S ACL35-S L35 L35-S L35S Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L35-S AC L35-S liquid nitrogen container AC L35-S cryogenic storage vessel AC L35-S Flüssigstickstoffbehälter AC L35-S Kryobehälter AC L35 S AC L35S ACL35-S ACL35S L35-S L35 S L35S L 35-S L 35 S L 35S AC L-35-S AC LS35 L35S AC AC L35 AC L 35 L35 AC L H-AAD1100251 HAAD1100251 H AAD1100251 H-AAD-1100251 AAD1100251 AAD 1100251 1100251 AC L35-S - MDR AC L35 S - MDR AC L35S MDR AC L 35-S - MDR AC L 35 S - MDR AC L 35S MDR ACL35-S MDR ACL35S MDR L35-S MDR L35 S MDR L35S MDR L 35-S MDR L 35 S MDR L 35S MDR AC L-35-S MDR AC LS35 MDR L35S MDR AC AC L35 MDR AC L 35 MDR L35 MDR AC L MDR H-AAD2100251 HAAD2100251 H AAD2100251 H-AAD-2100251 H-AAD 2100251 HAAD 2100251 AAD2100251 AAD 2100251 2100251 MDR M D R Medical Device Regulation\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 35,5\u003cbr\u003eEmpty weight (kg): 14,2\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 462\u003cbr\u003eTotal height (mm): 758\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 286\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299482235101,"sku":"AC L35-S","price":948.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299482267869,"sku":"AC L35-S - MDR","price":1137.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL35-S_Cell_Storage_Cryogenic_Nitrogen_Container_1.png?v=1793044694"},{"product_id":"ac-l35-l","title":"AC L35-L - Long Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 282.156px;\"\u003eAC L35-L\u003c\/th\u003e\n\u003cth style=\"width: 254.844px;\"\u003ePart No. H-AAD1100091\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e35,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e14,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e462\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e758\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e0,12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e286\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e2934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e1284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003e2ml Vials capacity\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e480*480*915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e0,211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 282.156px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 254.844px;\"\u003e18,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL35 ACL35L ACL35-L L35 L35-L L35L Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage MDR cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter Auguste Cryogenics AC L35-L AC L35-L liquid nitrogen container AC L35-L cryogenic storage vessel AC L35-L Flüssigstickstoffbehälter AC L35-L Kryobehälter AC L35 L AC L35L ACL35-L ACL35L L35-L L35 L L35L L 35-L L 35 L L 35L AC L-35-L AC LS35 L35L AC AC L35 AC L 35 L35 AC L H-AAD1100091 HAAD1100091 H AAD1100091 H-AAD-1100091 H-AAD 1100091 HAAD 1100091 AAD1100091 AAD 1100091 1100091 H-AAD2100091 HAAD2100091 H AAD2100091 H-AAD-2100091 H-AAD 2100091 HAAD 2100091 AAD2100091 AAD 2100091 2100091 MDR M D R Medical Device Regulation\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 35,5\u003cbr\u003eEmpty weight (kg): 14,2\u003cbr\u003eNeck opening (mm): 50\u003cbr\u003eOutside diameter (mm): 462\u003cbr\u003eTotal height (mm): 758\u003cbr\u003eStatic evaporation rate (liters \/ day): 0,12\u003cbr\u003eStatic hold time (days): 286\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299482857693,"sku":"AC L35-L","price":982.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299482890461,"sku":"AC L35-L - MDR","price":1178.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL35T-L_Cell_Transport_Cryogenic_Nitrogen_Container_1.png?v=1793044718"},{"product_id":"ac-l50t-s","title":"AC L50T-S - Short Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 555px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 277.891px;\" class=\"lefr-col\"\u003eAC L50T-S\u003c\/th\u003e\n\u003cth style=\"width: 259.109px;\"\u003ePart No. H-AAD1100107\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e17,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e462\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e825\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e0,24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e1788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e480*480*985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e0,227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 277.891px;\" class=\"lefr-col\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 259.109px;\"\u003e21,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 short canisters\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"77\" height=\"82\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL50 ACL50S ACL50-S L50 L50-S L50S ACL50T ACL50TS ACL50T-S L50T L50T-S L50TS Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter ADR Transportbehälter Transport Behälter Transport Zelltransport Probentransport transport container transport cell transport sample transport Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter MDR M D R Medical Device Regulation Auguste Cryogenics AC L50T-S AC L50T-S liquid nitrogen container AC L50T-S cryogenic storage vessel AC L50T-S Flüssigstickstoffbehälter AC L50T-S Kryobehälter AC L50T S AC L50TS ACL50T-S ACL50TS L50T-S L50T S L50TS L 50T-S L 50T S L 50TS AC L-50T-S AC LS50T L50TS AC AC L50T AC L 50T L50T AC L H-AAD1100107 HAAD1100107 H AAD1100107 H-AAD-1100107 H-AAD 1100107 HAAD 1100107 AAD1100107 AAD 1100107 1100107 H-AAD2100107 HAAD2100107 H AAD2100107 H-AAD-2100107 H-AAD 2100107 HAAD 2100107 AAD2100107 AAD 2100107 2100107\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 short canisters\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 50 \u003cbr\u003eEmpty weight (kg): 17,2 \u003cbr\u003eNeck opening (mm): 50 \u003cbr\u003eOutside diameter (mm): 462 \u003cbr\u003eTotal height (mm): 825 \u003cbr\u003eStatic evaporation rate (liters\/day): 0,24 \u003cbr\u003eStatic hold time (days): 209\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299484856541,"sku":"AC L50T-S","price":1369.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299484889309,"sku":"AC L50T-S - MDR","price":1643.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL50T-S_Cell_Transport_Cryogenic_Nitrogen_Container_1.png?v=1793044796"},{"product_id":"ac-l50t-l","title":"AC L50T-L - Long Canisters","description":"\u003cp\u003eThe vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh mobility due to low weight and compact dimensions\u003c\/li\u003e\n\u003cli\u003eLong holding times with low nitrogen consumption\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge storage capacity\u003c\/li\u003e\n\u003cli\u003eT-models with ADR approval – transportable in accordance with dangerous goods regulations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eA complete overview of all technical parameters for this container is provided in the “Technical Data” table below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOverview of further models for CELL STORAGE:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-t\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eT-Models\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003eT-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.\u003c\/p\u003e\n\u003cp\u003eExample: AC L20-S (standard) and AC L20T-S (T-version).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cryonos.shop\/collections\/ac-freezer\" rel=\"noopener\" target=\"_blank\"\u003eAC FREEZER\u003c\/a\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003cbr\u003eFreezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIf you need assistance selecting the appropriate container, please consult our guide \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e“\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/blogs\/cryogenic\/cryogenic-cell-storage-the-guide-to-selecting-the-right-container\" target=\"_blank\"\u003eCryogenic Cell Storage: The Guide to Selecting the Right Container\u003c\/a\u003e”\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cryonos.shop\/pages\/contact\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e directly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 555px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"lefr-col\" style=\"width: 281.891px;\"\u003eAC L50T-L\u003c\/th\u003e\n\u003cth style=\"width: 255.109px;\"\u003ePart No. H-AAD1100353\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eEmpty weight (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e17,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e462\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e825\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e0,24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eCanister diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eCanister height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eCanister Number\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e2934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml (-L)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e1284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003e2ml Vials capacity\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eADR\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eavailable as an MDR product\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003eyes (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003ePacking dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e480*480*985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eShipping volume (m3)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e0,227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 281.891px;\"\u003eWeight including packaging (kg)\u003c\/td\u003e\n\u003ctd style=\"width: 255.109px;\"\u003e21,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e* The values given are nominal values, determined without a storage system and under\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eprecisely defined conditions. Depending on the operating conditions and the\u003c\/em\u003e\u003cbr\u003e\u003cem\u003estorage system used, the actual values may vary considerably.\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eIn the course of continuous product improvement and development,\u003c\/em\u003e\u003cbr\u003e\u003cem\u003ewe reserve the right to change the specifications at any time without prior notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIncluding 6 long canisters and 12 goblets\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload datasheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC-Medical-brochure-EN.pdf?v=1603922394\" target=\"_blank\"\u003e\u003cimg height=\"82\" width=\"77\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords ACL ACL50 ACL50L ACL50-L L50 L50-L L50L ACL50T ACL50TL ACL50T-L L50T L50T-L L50TL Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter ADR Transportbehälter Transport Behälter Transport Zelltransport Probentransport transport container transport cell transport sample transport Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage Auguste Cryogenics AC L50T-L AC L50T-L liquid nitrogen container AC L50T-L cryogenic storage vessel AC L50T-L Flüssigstickstoffbehälter AC L50T-L Kryobehälter AC L50T L AC L50TL ACL50T-L ACL50TL L50T-L L50T L L50TL L 50T-L L 50T L L 50TL AC L-50T-L AC LS50T L50TL AC AC L50T AC L 50T L50T AC L H-AAD1100353 HAAD1100353 H AAD1100353 H-AAD-1100353 H-AAD 1100353 HAAD 1100353 AAD1100353 AAD 1100353 1100353 H-AAD2100353 HAAD2100353 H AAD2100353 H-AAD-2100353 H-AAD 2100353 HAAD 2100353 AAD2100353 AAD 2100353 2100353\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003eIncl. 6 long canisters and 12 goblets\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLN2 capacity (liters): 50 \u003cbr\u003eEmpty weight (kg): 17,2 \u003cbr\u003eNeck opening (mm): 50 \u003cbr\u003eOutside diameter (mm): 462 \u003cbr\u003eTotal height (mm): 825 \u003cbr\u003eStatic evaporation rate (liters\/day): 0,24 \u003cbr\u003eStatic hold time (days): 209\u003cbr\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":68299485216989,"sku":"AC L50T-L","price":1404.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":68299485249757,"sku":"AC L50T-L - MDR","price":1685.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/files\/ACL50T-L_Cell_Transport_Cryogenic_Nitrogen_Container_1.png?v=1793044807"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2200\/4701\/collections\/1.IMG_20191219_155039_2048x2048_f0053cc8-cbc8-4d07-9da8-e831ef53ca16.png?v=1793049098","url":"https:\/\/intl.cryonos.shop\/collections\/ac-l.oembed","provider":"Cryonos GmbH","version":"1.0","type":"link"}